On Tue, Dec 29, 2020 at 05:25:59PM +0100, Geert Uytterhoeven wrote: > Before, the maximum coordinates were fixed to (799, 479) or (319, 479), > depending on touchscreen controller type. The driver was changed to > read the actual values from the touchscreen controller, but did not take > into account the returned values are not the maximum coordinates, but > the touchscreen resolution (e.g. 800 and 480). > > Fix this by subtracting 1. > > Fixes: 3a54a215410b1650 ("Input: st1232 - add support resolution reading") > Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Applied, thank you. -- Dmitry
On Tue, Dec 29, 2020 at 05:26:01PM +0100, Geert Uytterhoeven wrote: > According to the st1232 datasheet, the host has to wait for the device > to change into Normal state before accessing registers other than the > Status Register. > > If the reset GPIO is wired, the device is powered on during driver > probe, just before reading the resolution. However, the latter may > happen before the device is ready, leading to a probe failure: > > st1232-ts 1-0055: Failed to read resolution: -6 > > Fix this by waiting until the device is ready, by trying to read the > Status Register until it indicates so, or until timeout. > > On Armadillo 800 EVA, typically the first read fails with an I2C > transfer error, while the second read indicates the device is ready. > > Fixes: 3a54a215410b1650 ("Input: st1232 - add support resolution reading") > Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Applied, thank you. -- Dmitry