@@ -290,17 +290,6 @@ static int aqr_read_status(struct phy_device *phydev)
return genphy_c45_read_status(phydev);
}
-static int aqr107_read_downshift_event(struct phy_device *phydev)
-{
- int val;
-
- val = phy_read_mmd(phydev, MDIO_MMD_AN, MDIO_AN_TX_VEND_INT_STATUS1);
- if (val < 0)
- return val;
-
- return !!(val & MDIO_AN_TX_VEND_INT_STATUS1_DOWNSHIFT);
-}
-
static int aqr107_read_rate(struct phy_device *phydev)
{
int val;
@@ -377,13 +366,7 @@ static int aqr107_read_status(struct phy_device *phydev)
break;
}
- val = aqr107_read_downshift_event(phydev);
- if (val <= 0)
- return val;
-
- phydev_warn(phydev, "Downshift occurred! Cabling may be defective.\n");
-
- /* Read downshifted rate from vendor register */
+ /* Read possibly downshifted rate from vendor register */
return aqr107_read_rate(phydev);
}
@@ -506,9 +489,6 @@ static int aqr107_config_init(struct phy_device *phydev)
if (!ret)
aqr107_chip_info(phydev);
- /* ensure that a latched downshift event is cleared */
- aqr107_read_downshift_event(phydev);
-
return aqr107_set_downshift(phydev, MDIO_AN_VEND_PROV_DOWNSHIFT_DFLT);
}
@@ -533,9 +513,6 @@ static int aqcs109_config_init(struct phy_device *phydev)
if (ret)
return ret;
- /* ensure that a latched downshift event is cleared */
- aqr107_read_downshift_event(phydev);
-
return aqr107_set_downshift(phydev, MDIO_AN_VEND_PROV_DOWNSHIFT_DFLT);
}
Now that phylib notifies the user of a downshift we can remove this functionality from the driver. Signed-off-by: Heiner Kallweit <hkallweit1@gmail.com> --- drivers/net/phy/aquantia_main.c | 25 +------------------------ 1 file changed, 1 insertion(+), 24 deletions(-)