diff mbox series

[v4,20/35] iommu/mediatek: Add a PM_CLK_AO flag for infra iommu

Message ID 20220125085634.17972-21-yong.wu@mediatek.com
State Accepted
Commit 6077c7e5d22f2e0ffdb1dd97bf37cba66f317627
Headers show
Series None | expand

Commit Message

Yong Wu (吴勇) Jan. 25, 2022, 8:56 a.m. UTC
The power/clock of infra iommu is always on, and it doesn't have the
device link with the master devices, then the infra iommu device's pm
statua is not active, thus we add A PM_CLK_AO flag for infra iommu.

The tlb operation is a bit not clear in this file, Comment them in the
code here.

Signed-off-by: Yong Wu <yong.wu@mediatek.com>
---
 drivers/iommu/mtk_iommu.c | 29 ++++++++++++++++++++++++++---
 1 file changed, 26 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/drivers/iommu/mtk_iommu.c b/drivers/iommu/mtk_iommu.c
index cf042ab74fa7..531f4750c721 100644
--- a/drivers/iommu/mtk_iommu.c
+++ b/drivers/iommu/mtk_iommu.c
@@ -130,6 +130,8 @@ 
 #define MTK_IOMMU_TYPE_MM		(0x0 << 13)
 #define MTK_IOMMU_TYPE_INFRA		(0x1 << 13)
 #define MTK_IOMMU_TYPE_MASK		(0x3 << 13)
+/* PM and clock always on. e.g. infra iommu */
+#define PM_CLK_AO			BIT(15)
 
 #define MTK_IOMMU_HAS_FLAG(pdata, _x)	(!!(((pdata)->flags) & (_x)))
 
@@ -235,13 +237,33 @@  static void mtk_iommu_tlb_flush_range_sync(unsigned long iova, size_t size,
 					   struct mtk_iommu_data *data)
 {
 	struct list_head *head = data->hw_list;
+	bool check_pm_status;
 	unsigned long flags;
 	int ret;
 	u32 tmp;
 
 	for_each_m4u(data, head) {
-		if (pm_runtime_get_if_in_use(data->dev) <= 0)
-			continue;
+		/*
+		 * To avoid resume the iommu device frequently when the iommu device
+		 * is not active, it doesn't always call pm_runtime_get here, then tlb
+		 * flush depends on the tlb flush all in the runtime resume.
+		 *
+		 * There are 2 special cases:
+		 *
+		 * Case1: The iommu dev doesn't have power domain but has bclk. This case
+		 * should also avoid the tlb flush while the dev is not active to mute
+		 * the tlb timeout log. like mt8173.
+		 *
+		 * Case2: The power/clock of infra iommu is always on, and it doesn't
+		 * have the device link with the master devices. This case should avoid
+		 * the PM status check.
+		 */
+		check_pm_status = !MTK_IOMMU_HAS_FLAG(data->plat_data, PM_CLK_AO);
+
+		if (check_pm_status) {
+			if (pm_runtime_get_if_in_use(data->dev) <= 0)
+				continue;
+		}
 
 		spin_lock_irqsave(&data->tlb_lock, flags);
 		writel_relaxed(F_INVLD_EN1 | F_INVLD_EN0,
@@ -268,7 +290,8 @@  static void mtk_iommu_tlb_flush_range_sync(unsigned long iova, size_t size,
 			mtk_iommu_tlb_flush_all(data);
 		}
 
-		pm_runtime_put(data->dev);
+		if (check_pm_status)
+			pm_runtime_put(data->dev);
 	}
 }