@@ -298,13 +298,13 @@ static int __thermal_of_unbind(struct device_node *map_np, int index, int trip_i
ret = of_parse_phandle_with_args(map_np, "cooling-device", "#cooling-cells",
index, &cooling_spec);
- of_node_put(cooling_spec.np);
-
if (ret < 0) {
pr_err("Invalid cooling-device entry\n");
return ret;
}
+ of_node_put(cooling_spec.np);
+
if (cooling_spec.args_count < 2) {
pr_err("wrong reference to cooling device, missing limits\n");
return -EINVAL;
@@ -331,13 +331,13 @@ static int __thermal_of_bind(struct device_node *map_np, int index, int trip_id,
ret = of_parse_phandle_with_args(map_np, "cooling-device", "#cooling-cells",
index, &cooling_spec);
- of_node_put(cooling_spec.np);
-
if (ret < 0) {
pr_err("Invalid cooling-device entry\n");
return ret;
}
+ of_node_put(cooling_spec.np);
+
if (cooling_spec.args_count < 2) {
pr_err("wrong reference to cooling device, missing limits\n");
return -EINVAL;