diff mbox series

[3/3] arch/arm/boot/dts/dra7.dtsi: add missing unit addresses

Message ID 20240122111948.416444-3-romain.naour@smile.fr
State New
Headers show
Series [1/3] arch/arm/boot/dts/dra7-l4.dtsi: add missing unit addresse | expand

Commit Message

Romain Naour Jan. 22, 2024, 11:19 a.m. UTC
From: Romain Naour <romain.naour@skf.com>

abb_{mpu,ivahd,dspeve,gpu} have 'reg' so they must have unit address.

Fixes:
Warning (unit_address_vs_reg): /ocp/regulator-abb-mpu: node has a reg or ranges property, but no unit name
Warning (unit_address_vs_reg): /ocp/regulator-abb-ivahd: node has a reg or ranges property, but no unit name
Warning (unit_address_vs_reg): /ocp/regulator-abb-dspeve: node has a reg or ranges property, but no unit name
Warning (unit_address_vs_reg): /ocp/regulator-abb-gpu: node has a reg or ranges property, but no unit name

Signed-off-by: Romain Naour <romain.naour@skf.com>
---
 arch/arm/boot/dts/ti/omap/dra7.dtsi | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)
diff mbox series

Patch

diff --git a/arch/arm/boot/dts/ti/omap/dra7.dtsi b/arch/arm/boot/dts/ti/omap/dra7.dtsi
index 6509c742fb58..565ac7691a2a 100644
--- a/arch/arm/boot/dts/ti/omap/dra7.dtsi
+++ b/arch/arm/boot/dts/ti/omap/dra7.dtsi
@@ -638,7 +638,7 @@  mmu_ipu2: mmu@0 {
 			};
 		};
 
-		abb_mpu: regulator-abb-mpu {
+		abb_mpu: regulator-abb-mpu@4ae07ddc {
 			compatible = "ti,abb-v3";
 			regulator-name = "abb_mpu";
 			#address-cells = <0>;
@@ -671,7 +671,7 @@  abb_mpu: regulator-abb-mpu {
 			>;
 		};
 
-		abb_ivahd: regulator-abb-ivahd {
+		abb_ivahd: regulator-abb-ivahd@4ae07e34 {
 			compatible = "ti,abb-v3";
 			regulator-name = "abb_ivahd";
 			#address-cells = <0>;
@@ -704,7 +704,7 @@  abb_ivahd: regulator-abb-ivahd {
 			>;
 		};
 
-		abb_dspeve: regulator-abb-dspeve {
+		abb_dspeve: regulator-abb-dspeve@4ae07e30 {
 			compatible = "ti,abb-v3";
 			regulator-name = "abb_dspeve";
 			#address-cells = <0>;
@@ -737,7 +737,7 @@  abb_dspeve: regulator-abb-dspeve {
 			>;
 		};
 
-		abb_gpu: regulator-abb-gpu {
+		abb_gpu: regulator-abb-gpu@4ae07de4 {
 			compatible = "ti,abb-v3";
 			regulator-name = "abb_gpu";
 			#address-cells = <0>;