diff mbox series

[2/2] HID: i2c-hid: Use address probe to wake on resume

Message ID 20240429233924.6453-3-kl@kl.wtf
State Accepted
Commit 7d6f065de37c31c37e56611efd41260c66c868ca
Headers show
Series HID: i2c-hid: Unify device wake-up logic | expand

Commit Message

Kenny Levinsen April 29, 2024, 11:33 p.m. UTC
Certain devices, both from STM and Weida Tech, need to be woken up after
having entered a deeper sleep state. The relevant places to wake up such
device is during our initial HID probe, and after resuming.

A retry for power commands was previously added to i2c_hid_set_power to
wake up Weida Tech devices, but lacked sufficient sleep for STM devices.
Replace the power command retry with the same address probe we using
during our initial HID probe.

Signed-off-by: Kenny Levinsen <kl@kl.wtf>
---
 drivers/hid/i2c-hid/i2c-hid-core.c | 21 ++++++++-------------
 1 file changed, 8 insertions(+), 13 deletions(-)
diff mbox series

Patch

diff --git a/drivers/hid/i2c-hid/i2c-hid-core.c b/drivers/hid/i2c-hid/i2c-hid-core.c
index a40489bb7643..3e3885ae6ce2 100644
--- a/drivers/hid/i2c-hid/i2c-hid-core.c
+++ b/drivers/hid/i2c-hid/i2c-hid-core.c
@@ -402,19 +402,6 @@  static int i2c_hid_set_power(struct i2c_hid *ihid, int power_state)
 
 	i2c_hid_dbg(ihid, "%s\n", __func__);
 
-	/*
-	 * Some devices require to send a command to wakeup before power on.
-	 * The call will get a return value (EREMOTEIO) but device will be
-	 * triggered and activated. After that, it goes like a normal device.
-	 */
-	if (power_state == I2C_HID_PWR_ON) {
-		ret = i2c_hid_set_power_command(ihid, I2C_HID_PWR_ON);
-
-		/* Device was already activated */
-		if (!ret)
-			goto set_pwr_exit;
-	}
-
 	ret = i2c_hid_set_power_command(ihid, power_state);
 	if (ret)
 		dev_err(&ihid->client->dev,
@@ -977,6 +964,14 @@  static int i2c_hid_core_resume(struct i2c_hid *ihid)
 
 	enable_irq(client->irq);
 
+	/* Make sure the device is awake on the bus */
+	ret = i2c_hid_probe_address(ihid);
+	if (ret < 0) {
+		dev_err(&client->dev, "nothing at address after resume: %d\n",
+			ret);
+		return -ENXIO;
+	}
+
 	/* Instead of resetting device, simply powers the device on. This
 	 * solves "incomplete reports" on Raydium devices 2386:3118 and
 	 * 2386:4B33 and fixes various SIS touchscreens no longer sending