@@ -150,8 +150,18 @@ config THERMAL_GOV_POWER_ALLOCATOR
config CPU_THERMAL
bool "Generic cpu cooling support"
- depends on CPU_FREQ
depends on THERMAL_OF
+ help
+ Enable the CPU cooling features. If the system has no active
+ cooling device available, this option allows to use the CPU
+ as a cooling device.
+
+if CPU_THERMAL
+
+config CPU_FREQ_THERMAL
+ bool "CPU frequency cooling device"
+ depends on CPU_FREQ
+ default y
help
This implements the generic cpu cooling mechanism through frequency
reduction. An ACPI version of this already exists
@@ -159,7 +169,7 @@ config CPU_THERMAL
This will be useful for platforms using the generic thermal interface
and not the ACPI interface.
- If you want this support, you should say Y here.
+endif
config CLOCK_THERMAL
bool "Generic clock cooling support"
@@ -19,7 +19,7 @@ thermal_sys-$(CONFIG_THERMAL_GOV_USER_SPACE) += user_space.o
thermal_sys-$(CONFIG_THERMAL_GOV_POWER_ALLOCATOR) += power_allocator.o
# cpufreq cooling
-thermal_sys-$(CONFIG_CPU_THERMAL) += cpu_cooling.o
+thermal_sys-$(CONFIG_CPU_FREQ_THERMAL) += cpu_cooling.o
# clock cooling
thermal_sys-$(CONFIG_CLOCK_THERMAL) += clock_cooling.o
@@ -19,7 +19,7 @@
struct cpufreq_policy;
-#ifdef CONFIG_CPU_THERMAL
+#ifdef CONFIG_CPU_FREQ_THERMAL
/**
* cpufreq_cooling_register - function to create cpufreq cooling device.
* @policy: cpufreq policy.
@@ -40,7 +40,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev);
struct thermal_cooling_device *
of_cpufreq_cooling_register(struct cpufreq_policy *policy);
-#else /* !CONFIG_CPU_THERMAL */
+#else /* !CONFIG_CPU_FREQ_THERMAL */
static inline struct thermal_cooling_device *
cpufreq_cooling_register(struct cpufreq_policy *policy)
{
@@ -58,6 +58,6 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy)
{
return NULL;
}
-#endif /* CONFIG_CPU_THERMAL */
+#endif /* CONFIG_CPU_FREQ_THERMAL */
#endif /* __CPU_COOLING_H__ */