diff mbox series

[2/5] wireless-regdb: Update regulatory info for Peru (PE) on 6GHz

Message ID 20240705060613.28909-2-pkshih@gmail.com
State Superseded
Headers show
Series [1/5] wireless-regdb: Update regulatory info for New Zealand (NZ) for 2022 | expand

Commit Message

Ping-Ke Shih July 5, 2024, 6:06 a.m. UTC
From: Ping-Ke Shih <pkshih@realtek.com>

Ministerial Resolution -2021-MTC/01 decided

For the band 5925-7125 MHz, low power indoor case of use.
 - access point
   maximum EIRP: 30 dBm
   Limited power spectral density: 5 dBm / MHz
 - user devices
   maximum EIRP: 24 dBm
   Limited power spectral density: -1 dBm / MHz

[1] https://cdn.www.gob.pe/uploads/document/file/1861732/Resoluci%C3%B3n%20Ministerial%20nro%20373-2021-MTC/01.pdf

Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
---
 db.txt | 3 +++
 1 file changed, 3 insertions(+)

Comments

Chen-Yu Tsai July 18, 2024, 4:41 a.m. UTC | #1
On Fri, Jul 5, 2024 at 2:06 PM Ping-Ke Shih <pkshih@gmail.com> wrote:
>
> From: Ping-Ke Shih <pkshih@realtek.com>
>
> Ministerial Resolution -2021-MTC/01 decided
>
> For the band 5925-7125 MHz, low power indoor case of use.
>  - access point
>    maximum EIRP: 30 dBm
>    Limited power spectral density: 5 dBm / MHz
>  - user devices
>    maximum EIRP: 24 dBm
>    Limited power spectral density: -1 dBm / MHz

Please explicitly mention that the PSD limits the rule to 12 dBm.

Otherwise this looks good.

ChenYu

> [1] https://cdn.www.gob.pe/uploads/document/file/1861732/Resoluci%C3%B3n%20Ministerial%20nro%20373-2021-MTC/01.pdf
>
> Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
> ---
>  db.txt | 3 +++
>  1 file changed, 3 insertions(+)
>
> diff --git a/db.txt b/db.txt
> index 266ba2d48731..2e862b322f13 100644
> --- a/db.txt
> +++ b/db.txt
> @@ -1443,12 +1443,15 @@ country PA: DFS-FCC
>         (5725 - 5850 @ 80), (36)
>         (57000 - 64000 @ 2160), (43)
>
> +# Source:
> +# https://cdn.www.gob.pe/uploads/document/file/1861732/Resoluci%C3%B3n%20Ministerial%20nro%20373-2021-MTC/01.pdf
>  country PE: DFS-FCC
>         (2402 - 2482 @ 40), (20)
>         (5170 - 5250 @ 80), (17), AUTO-BW
>         (5250 - 5330 @ 80), (24), DFS, AUTO-BW
>         (5490 - 5730 @ 160), (24), DFS
>         (5735 - 5835 @ 80), (30)
> +       (5925 - 7125 @ 320), (12), NO-OUTDOOR
>
>  country PF: DFS-ETSI
>         (2402 - 2482 @ 40), (20)
> --
> 2.25.1
>
diff mbox series

Patch

diff --git a/db.txt b/db.txt
index 266ba2d48731..2e862b322f13 100644
--- a/db.txt
+++ b/db.txt
@@ -1443,12 +1443,15 @@  country PA: DFS-FCC
 	(5725 - 5850 @ 80), (36)
 	(57000 - 64000 @ 2160), (43)
 
+# Source:
+# https://cdn.www.gob.pe/uploads/document/file/1861732/Resoluci%C3%B3n%20Ministerial%20nro%20373-2021-MTC/01.pdf
 country PE: DFS-FCC
 	(2402 - 2482 @ 40), (20)
 	(5170 - 5250 @ 80), (17), AUTO-BW
 	(5250 - 5330 @ 80), (24), DFS, AUTO-BW
 	(5490 - 5730 @ 160), (24), DFS
 	(5735 - 5835 @ 80), (30)
+	(5925 - 7125 @ 320), (12), NO-OUTDOOR
 
 country PF: DFS-ETSI
 	(2402 - 2482 @ 40), (20)