From patchwork Fri Nov 17 16:42:05 2023 Content-Type: text/plain; charset="utf-8" MIME-Version: 1.0 Content-Transfer-Encoding: 7bit X-Patchwork-Submitter: Petre Rodan X-Patchwork-Id: 744753 Authentication-Results: smtp.subspace.kernel.org; dkim=pass (1024-bit key) header.d=subdimension.ro header.i=@subdimension.ro header.b="KzLG9mzb" X-Greylist: delayed 464 seconds by postgrey-1.37 at lindbergh.monkeyblade.net; Fri, 17 Nov 2023 08:50:55 PST Received: from mail.subdimension.ro (skycaves.subdimension.ro [172.104.132.142]) by lindbergh.monkeyblade.net (Postfix) with ESMTPS id 64277D56; Fri, 17 Nov 2023 08:50:55 -0800 (PST) Received: from localhost.localdomain (unknown [188.24.94.216]) (using TLSv1.3 with cipher TLS_AES_256_GCM_SHA384 (256/256 bits) key-exchange X25519 server-signature RSA-PSS (4096 bits) server-digest SHA256) (Client did not present a certificate) by mail.subdimension.ro (Postfix) with ESMTPSA id 9F67828F040; Fri, 17 Nov 2023 16:43:06 +0000 (UTC) DKIM-Signature: v=1; a=rsa-sha256; c=relaxed/simple; d=subdimension.ro; s=skycaves; t=1700239386; bh=QT8vpu+ylcxkag8lhmcsJJ4NYnz4R5VzA35fbKzvegw=; h=From:To:Cc:Subject:Date; b=KzLG9mzbk+hWS8oRpqEdF1tdUD+MXGnWAHpfXJv9gHmgxJRzWGsSxxrsd0Nekco0C 6M/W5hHuVzMAim1hPU9h6PetYh7L3opB3w3T04s8eC5mjMKYmzyz8LiDcMt05yfQ6J +YEWRAUQJRymrrJCaWtQllJD9LB/xMl0234dafvs= From: Petre Rodan To: petre.rodan@subdimension.ro, linux-kernel@vger.kernel.org, linux-iio@vger.kernel.org, devicetree@vger.kernel.org Cc: Conor Dooley , Lars-Peter Clausen , Rob Herring , Krzysztof Kozlowski , linux-kernel-mentees@lists.linuxfoundation.org, Jonathan Cameron Subject: [PATCH 1/2] dt-bindings: iio: pressure: add honeywell,hsc030 Date: Fri, 17 Nov 2023 18:42:05 +0200 Message-ID: <20231117164232.8474-1-petre.rodan@subdimension.ro> X-Mailer: git-send-email 2.41.0 Precedence: bulk X-Mailing-List: devicetree@vger.kernel.org List-Id: List-Subscribe: List-Unsubscribe: MIME-Version: 1.0 Adds binding for digital Honeywell TruStability HSC and SSC series pressure and temperature sensors. Datasheet: [HSC] https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-hsc-series/documents/sps-siot-trustability-hsc-series-high-accuracy-board-mount-pressure-sensors-50099148-a-en-ciid-151133.pdf [SSC] https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-ssc-series/documents/sps-siot-trustability-ssc-series-standard-accuracy-board-mount-pressure-sensors-50099533-a-en-ciid-151134.pdf Signed-off-by: Petre Rodan --- .../iio/pressure/honeywell,hsc030pa.yaml | 166 ++++++++++++++++++ 1 file changed, 166 insertions(+) create mode 100644 Documentation/devicetree/bindings/iio/pressure/honeywell,hsc0030pa.yaml diff --git a/Documentation/devicetree/bindings/iio/pressure/honeywell,hsc030pa.yaml b/Documentation/devicetree/bindings/iio/pressure/honeywell,hsc030pa.yaml new file mode 100644 index 000000000000..777710790696 --- /dev/null +++ b/Documentation/devicetree/bindings/iio/pressure/honeywell,hsc030pa.yaml @@ -0,0 +1,166 @@ +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) +%YAML 1.2 +--- +$id: http://devicetree.org/schemas/iio/pressure/honeywell,hsc030pa.yaml# +$schema: http://devicetree.org/meta-schemas/core.yaml# + +title: Honeywell TruStability HSC and SSC pressure sensor families + +maintainers: + - Petre Rodan + +description: | + support for Honeywell TruStability HSC and SSC digital pressure sensor + families. + + These sensors have either an I2C, an SPI or an analog interface. Only the + digital versions are supported by this driver. + + There are 118 models with different pressure ranges available in each family. + The vendor calls them "HSC series" and "SSC series". All of them have an + identical programming model but differ in pressure range, unit and transfer + function. + + To support different models one need to specify the pressure range as well as + the transfer function. Pressure range can either be provided via range_str or + in case it's a custom chip via numerical range limits converted to pascals. + + The transfer function defines the ranges of raw conversion values delivered + by the sensor. pmin-pascal and pmax-pascal corespond to the minimum and + maximum pressure that can be measured. + + Specifications about the devices can be found at: + https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-hsc-series/documents/sps-siot-trustability-hsc-series-high-accuracy-board-mount-pressure-sensors-50099148-a-en-ciid-151133.pdf + https://prod-edam.honeywell.com/content/dam/honeywell-edam/sps/siot/en-us/products/sensors/pressure-sensors/board-mount-pressure-sensors/trustability-ssc-series/documents/sps-siot-trustability-ssc-series-standard-accuracy-board-mount-pressure-sensors-50099533-a-en-ciid-151134.pdf + +properties: + compatible: + enum: + - honeywell,hsc + - honeywell,ssc + + reg: + maxItems: 1 + + honeywell,transfer-function: + description: | + Transfer function which defines the range of valid values delivered by + the sensor. + 0 - A, 10% to 90% of 2^14 + 1 - B, 5% to 95% of 2^14 + 2 - C, 5% to 85% of 2^14 + 3 - F, 4% to 94% of 2^14 + $ref: /schemas/types.yaml#/definitions/uint32 + + honeywell,range_str: + description: | + Five character string that defines "pressure range, unit and type" + as part of the device nomenclature. In the unlikely case of a custom + chip, set to "NA" and provide honeywell,pmin-pascal honeywell,pmax-pascal + enum: [ "001BA", "1.6BA", "2.5BA", "004BA", "006BA", "010BA", "1.6MD", + "2.5MD", "004MD", "006MD", "010MD", "016MD", "025MD", "040MD", + "060MD", "100MD", "160MD", "250MD", "400MD", "600MD", "001BD", + "1.6BD", "2.5BD", "004BD", "2.5MG", "004MG", "006MG", "010MG", + "016MG", "025MG", "040MG", "060MG", "100MG", "160MG", "250MG", + "400MG", "600MG", "001BG", "1.6BG", "2.5BG", "004BG", "006BG", + "010BG", "100KA", "160KA", "250KA", "400KA", "600KA", "001GA", + "160LD", "250LD", "400LD", "600LD", "001KD", "1.6KD", "2.5KD", + "004KD", "006KD", "010KD", "016KD", "025KD", "040KD", "060KD", + "100KD", "160KD", "250KD", "400KD", "250LG", "400LG", "600LG", + "001KG", "1.6KG", "2.5KG", "004KG", "006KG", "010KG", "016KG", + "025KG", "040KG", "060KG", "100KG", "160KG", "250KG", "400KG", + "600KG", "001GG", "015PA", "030PA", "060PA", "100PA", "150PA", + "0.5ND", "001ND", "002ND", "004ND", "005ND", "010ND", "020ND", + "030ND", "001PD", "005PD", "015PD", "030PD", "060PD", "001NG", + "002NG", "004NG", "005NG", "010NG", "020NG", "030NG", "001PG", + "005PG", "015PG", "030PG", "060PG", "100PG", "150PG", "NA" ] + $ref: /schemas/types.yaml#/definitions/string + + honeywell,pmin-pascal: + description: | + Minimum pressure value the sensor can measure in pascal. + To be specified only if honeywell,range_str is set to "NA". + $ref: /schemas/types.yaml#/definitions/int32 + + honeywell,pmax-pascal: + description: | + Maximum pressure value the sensor can measure in pascal. + To be specified only if honeywell,range_str is set to "NA". + $ref: /schemas/types.yaml#/definitions/int32 + + vdd-supply: + description: | + Provide VDD power to the sensor (either 3.3V or 5V depending on the chip). + Optional, activate only if required by the target board. + + spi-max-frequency: + description: SPI clock to be kept between 50 and 800kHz + + clock-frequency: + description: i2c clock to be kept between 100 and 400kHz + +required: + - compatible + - reg + - honeywell,transfer-function + - honeywell,range_str + - clock-frequency + - spi-max-frequency + +additionalProperties: false + +examples: + - | + #include + i2c { + status = "okay"; + clock-frequency = <400000>; + #address-cells = <1>; + #size-cells = <0>; + + HSCMRNN030PA2A3@28 { + status = "okay"; + compatible = "honeywell,hsc"; + reg = <0x28>; + honeywell,transfer-function = <0>; + honeywell,range_str = "030PA"; + honeywell,pmin-pascal = <0>; + honeywell,pmax-pascal = <206850>; + + //vdd-supply = <&foo>; + }; + }; + + spi { + # note that MOSI is not required by this sensor + status = "okay"; + #address-cells = <1>; + #size-cells = <0>; + pinctrl-names = "default"; + pinctrl-0 = <&spi0_pins>; + + channel@0{ + status = "disabled"; + reg = <0>; + }; + + HSCMLNN100PASA3@0 { + status = "okay"; + compatible = "honeywell,hsc"; + reg = <0>; + spi-max-frequency = <800000>; + + honeywell,transfer-function = <0>; + honeywell,range_str = "100PA"; + + // in case of a custom range, use NA as range_str + // and populate pmin-pascal and pmax-pascal + // with the range limits converted into pascals + //honeywell,range_str = "NA"; + //honeywell,pmin-pascal = <0>; + //honeywell,pmax-pascal = <206850>; + + //vdd-supply = <&foo>; + }; + }; +